Physical volume library robot not found
Webb19 okt. 2012 · Invalid Physical Volume Library Media Identifier. V-79-57344-33029 - Unable to acquire device for the specified pool and media The backup to Disk is running fine, but I can't copy them to tape. Webb10 jan. 2006 · I did run an Inventory test on the Device, and i did get the error message "Physical Volume Library Drive or Robot paused, offline, or disabled". I did all the following tests: - The device appears online on Backup Exec - The Tape Drive appears on Device Manager, and shows working correctly - I did reboot the tape drive and the server many …
Physical volume library robot not found
Did you know?
Webb13 jan. 2012 · There should be a medium changer which would be listed in the device manager. Once the OS detect the medium changer you should see the library in the … Webb10 maj 2007 · I had a working environment looking like this: Windows 2003 Server Std. SP1 SQL 2000 SP4 (was only running Axapta, our ERP software) Axapta 3.0 SP4 Veritas Backup Exec 10.0 SP3 (not using the SQL 2000 Server but instead the SQL Desktop Edition that comes with it) Sony LIB-81 Library connected to a...
Webb29 maj 2024 · Invalid Physical Volume Library Robot Identifier V-79-57344-33030 - Unable to acquire device for the specified pool and media Invalid Physical Volume Library Robot Identifier Cause This error may occur due to possible corruption in the catalog folder or faulty tape hardware. Solution Perform the following troubleshooting steps: 1. Webb14 sep. 2006 · Check you application and system log. When you rebooted the library was not detected by the OS or there were some problem and now backup exec cant communicate with the library. Power down "completely off" the server and library and power back up. LawnBoy (MIS) 14 Sep 06 11:31
Webb18 aug. 2014 · Power up the tape library 3. Power up the media server 4. Check that the tape library is functioning correctly in the Device Manager. 08-17-2014 11:47 PM. 1. Run tapeinst.exe to make sure that the Symantec drivers have been installed for the tape drive. Also make sure that in Device Manager, the robotics of the autoloader shows up as …
Webb28 jan. 2024 · Solution The medium changer and storage controllers should be listed in the Windows Device Manager and should not show up with any error/warning signs. Perform …
Webb7 okt. 2015 · 1) Do both 1 and 2 which will use even more tape storage but will give both the DR and the file by file restore requirements. 2) Have a second Backup Exec Server also running Deduplication with a CASO/ESO setup and duplicate the backups between deduplication stores (as well as doing tape duplication if offsite storage needed) … stq womens trainers reviewWebb16 feb. 2005 · This issue may also occur, if the robotic arm does not release the SCSI bus after any device operation. Solution: Alternative 1: Re-initialize the robotic library. - Power cycle tape library and the server (reboot). - Perform inventory of each slots separately Alternative 2: Modify registry settings: rothley 52 ceiling fanWebb7 nov. 2006 · I got this error "e0008115 - Physical Volume Library Drive or Robot paused, offline, or disabled" and now the drive is not working, all my other three drives work just … roth lets do itWebb19 dec. 2006 · Physical Volume Library Robot not found. HELP! I am running BE 10.0 on a W2K SP4 server (Dell 2550) with a SCSI attached LTO3 Tape Library. Last week, I … stq womens trainersWebb3 dec. 2010 · The clue was when I ran an Inventory on the drive, it errored out: Final error: 0xe0008113 - Physical Volume Library Robot not found. This truly was a standalone drive and not a robotic drive or library, so I figured I would run the Robotic library configuration wizard and add this drive to the library and then remove it. rothlerwirt rothWebb13 jan. 2012 · There should be a medium changer which would be listed in the device manager. Once the OS detect the medium changer you should see the library in the devices tab of backup exec console. But if you have just 1 drive in the library it should show only 1 in device manager. Check the connections and try... rothley 19mm railWebb28 jan. 2024 · Solution The medium changer and storage controllers should be listed in the Windows Device Manager and should not show up with any error/warning signs. Perform the following steps to resolve this issue: Go to Windows Device Manager Confirm that the medium changer and storage controllers are detected without any error/warning signs. stqy 字体